A shaver socket-outlet with a transformer is called a shaver supply unit. The term 'shaver supply unit' means: an accessory embodying a shaver transformer and one or more socket-outlets. A shaver supply unit complying with BS EN 61558-2-5 may be installed in zone 2 of a location containing a bath or shower (Regulation 701.512.3 refers).
This is the specification for industrial and domestic safety isolating transformers). Low voltage shaver sockets should only be used in a bathroom. In accordance with the updated 17 th edition of the IEE Wiring Regulations, it is safe to install electric shaver sockets in your bathroom providing the socket is 110v and installed in zone 2 or beyond.
Fitting an Electrical Shaver Point | How to Fit a Shaving Socket | DIY ...
Hi, I have a shaver socket that I plan to install above the basin in zone 2. The shaver socket is bs61558-2-5 compliant. Ok According to nic it says it's allowed but again I read on another bathroom website that only 110v is allowed? I'd like to know if I can install a 110/230v shaver socket.
Learn how to add a shaver socket to your bathroom with this step-by-step guide. From choosing the right socket to wiring it correctly, we'll walk you through the process, so you can safely and easily install a convenient shaver socket in your bathroom. Shaver sockets are a practical addition to UK bathrooms, but they must be installed following strict safety regulations.
What are Bathroom Electrical Zones? | Big Bathroom Inspiration
From understanding bathroom zones to ensuring RCD protection, following the correct guidelines is crucial to avoid hazards. For safe and compliant electrical installations, trust Wave Electrical Solutions to get the job done. Shaver sockets should be installed 300mm from the edge of the sink unit, or you can site the shaver socket in zone 2 which runs from the edge of the bath or shower cubicle to a distance of 600mm from the bath / shower cubicle up to the height of 2.25m.
We have one but I want to replace it. There seems to be some confusion over whether this is allowed in Zone 2. It is the type with an isolating transformer but is only rated IP2X, so no moisture ingress rating.
Bathroom Electrical Regulations (UK) | Everything You Need To Know
does anyone have a view? Presuambly the old unit was fitted as compliant but this was. Zone 2 - The only switchgear and socket outlets that can be installed in Zone 2 are the switches and socket outlets of SELV circuits that have a safety source installed outside Zones 0, 1 and 2, and shaver socket outlets to BS EN 61558. Is it possible to install a shaver socket in Zone 2? Electric shaver sockets are safe to install in your bathroom if the socket is 110v and installed in zone 2 or higher, with at least a 3-meter gap from either the bath or shower, according to the updated 17th edition of the IEE Wiring Regulations.
You can site the shaver socket in Zone 2, which runs from the edge of the bath or shower cubicle to a distance of 600mm from the bath or shower cubicle, up to a height of 2.25m. Some organisations extend Zone 2 to around the wash basin: If you would prefer to keep your shaver socket out of this area, by all means do.